青草国产精品久久久久久,男女做AJ视频免费的网站 ,美女视频黄又黄又免费,日本xxwwwxxxx18

NP800系列

NP800系列產(chǎn)品為CEE繼電器全新升級(jí)產(chǎn)品,NP800繼電器為人、網(wǎng)絡(luò)和電氣裝置提供保護(hù),并允許與SCADA系統(tǒng)通信。多功能NP800繼電器除了提供以前系列的常規(guī)保護(hù)功能外,還提供網(wǎng)絡(luò)電量的監(jiān)視、測(cè)量和記錄。

NP800系列

產(chǎn)品簡(jiǎn)介

NP800-01-A.jpg

我們?cè)陟o電繼電器和數(shù)字繼電器的電網(wǎng)保護(hù)領(lǐng)域的技術(shù)訣竅使新一代產(chǎn)品的開(kāi)發(fā)符合最苛刻的質(zhì)量標(biāo)準(zhǔn)和最新的技術(shù)概念。這項(xiàng)專(zhuān)長(zhǎng)的結(jié)果之一是數(shù)值NP800繼電器范圍。


NP800繼電器為人、網(wǎng)絡(luò)和電氣裝置提供保護(hù),并允許與SCADA系統(tǒng)通信。多功能NP800繼電器除了提供以前系列的常規(guī)保護(hù)功能外,還提供網(wǎng)絡(luò)電量的監(jiān)視、測(cè)量和記錄。


NP800系列的共同特征:



Our know-how in the domain of electrical network protection by static and numerical relays has led to the development of new generations of products that comply with the most demanding quality standards and the most recent technological concepts. One of the results of this expertise is the numerical NP800 relay range.

The NP800 relays provide the protection of people, networks and electric installations and they allow communication with SCADA systems. As well as the usual protection functions of former ranges, the multifunctional NP800 relays provide monitoring, measurement and recording of the network electrical quantities.


Common characteristics for the NP800 range:


Auxiliary supply ranges: 19V to 70V or 85V to 255V (AC or DC)

2 setting tables

Self-diagnosis: RAM, ROM, EEPROM, output relays, A/D converters, auxiliary supply, monitoring of software execution time

Optional I/O extension board (included when directional function is present)

Setting, reading, measuring and recording are all available locally or remotely

Complies with IEC 60255-4 standard.

Monitoring of circuit breaker failure

Event recording: 250 events, 10ms resolution

4 disturbance recordings in COMTRADE format

 DispositivoANSIDescrizione
NPG80021, 24, 27, 32, 37, 40, 46, 49, 50, 51, 50V, 51V, 59, 59N, 64, 81, 50BF, 74TC, 86Multi function generator protection
NPI80046, 46BC, 49, 50, 50N, 50BF, 51, 51N, 86, 74TCPhase and Earth Overcurrent Protection
NPID80046, 46BC, 49, 50, 50N, 50BF, 51, 51N, 67, 67N, 86, 74TCPhase and Earth Overcurrent Protection with directional criteria
NPIH80050N, 50NBF, 51N, 86, 74TCEarth Overcurrent Relay
NPIHD80050N, 50NBF, 51N, 67N, 86, 74TCEarth Overcurrent Relay with directional criteria
NPU80027, 27P, 47, 59, 59N, 74TC, 81, 86Voltage and Frequency Relay
NPUH80059N, 86, 74TCResidual Overvoltage Relay (Neutral Displacement Relay)
NPM80037I, 46, 48, 49, 5/49, 50, 50BF, 51LR, 51N, 66, 86, 74TCMulti function motor protection
NPRG810-1G
NPRG810-4G
25, step up transformer adaptationGenerator Synchro-check relay
NPRG860
NPRG870
25, 90, step up transformer adaptationAutomatic synchronizer device for up to 4 generators
NPSC800-1
NPSC800-2
25
25 + network managment
Network Check Synchronizing Relay
NPW80032, 37, 27, 59, 59N, 55, 81, 86, 74TC, BF



資料下載


NP800-NP800R系列產(chǎn)品手冊(cè)——點(diǎn)擊下載>>(英文版PDF格式)

武乡县| 内乡县| 三都| 大庆市| 府谷县| 射洪县| 伊川县| 健康| 延津县| 连州市|